Two doors used to swing as a pair at the community hall entrance, but one leaf has started closing before the other, catching the astragal and leaving a gap wide enough to worry the caretaker.

Call (289) 653-1447

In plain words

A tenant fit-out is a common point to bring exit hardware into a space for the first time. As walls move and a room's intended use becomes clear, the doors serving it get measured against that use: occupancy, fire rating, width and whether the space now qualifies as an assembly occupancy. Specifying and fitting the hardware alongside the rest of the fit-out, rather than after an inspector flags it, keeps the schedule intact and gives the space a documented exit from the day it opens.

Sound familiar?

The new access-control reader at the staff entrance works fine going in, but nobody has sorted out the door's exit side, and right now a card reader and a pushbar exist as two separate ideas.

How the visit goes

Panic & Exit Hardware

How the visit goes

White door with a black keypad deadbolt and knob, beside a towel holding a lock body, latch, screwdriver and a tool bag. — Beaverton
Technician in a cap and clear glasses holding a yellow impact driver at the latch edge of a black door. — Beaverton
  1. Occupancy, fire rating and the authority reviewing the space

    The assessment records the occupancy type and calculated occupant load for the room the door serves, whether the door sits in a fire separation, and who the authority having jurisdiction is likely to be, whether that is a fire inspector, a building official or an insurer. These facts, not the door's appearance or its width alone, are what decide whether a releasing device is required, whether it must also be fire-rated exit hardware, and what documentation the finished installation should carry.

  2. Handling a pair of doors

    On a pair, a coordinator is fitted only where the hardware needs the leaves to close in a set order, letting the active leaf's device seat into the strike or into an astragal carried on the inactive leaf; many pairs latch independently and skip this step entirely. Where the plan calls for one wide exit instead of two narrow ones, the centre mullion is removed and vertical-rod devices are fitted to each leaf instead, arranged so both close and latch reliably. Either way, both leaves are tested together, not only on their own, before the visit is called finished.

  3. A door that opens under one motion, every time

    What the space has afterward is straightforward: anyone inside can leave through that door with a single push on the crossbar or touchpad, no key, no second step, no need to remember which way a lock turns. Staff can be shown the motion once and it stays intuitive, because that is exactly what the hardware is built to do. Outside, entry still works the way it was set up to, through the trim chosen for that door, entirely separate from the exit function inside.

Panic & Exit Hardware

In the van

  • Dogging key or keyed cylinder

  • Door closer

  • Through-fixings and mounting hardware

  • Installation template and jig

  • Signage and labels

Two technicians in green shirts look over a metal tray holding a chrome tool beside a white van with open rear doors. — Beaverton

Panic & Exit Hardware

What affects the quote

  1. Occupancy and code documentation needed

    A project with a fire inspector's note or a building official's requirement attached usually needs a more detailed written record than a straightforward upgrade an owner requests on their own initiative.

  2. Weatherproofing for an exterior opening

    An exterior device, strike and trim built to handle temperature swings and moisture cost more as hardware than an equivalent interior-only set, and the quote reflects that difference in the parts themselves.

  3. Access to the opening

    A ground-floor commercial door is straightforward to reach. An opening behind scaffolding, up a stairwell with no elevator, or in a space still under active construction takes longer to work at.

What to have ready

  • Has a fire inspector or building official already flagged a specific door?
  • Does any door already have a hasp, padlock or extra deadbolt fitted?
  • Is this for new construction, a renovation, or an existing building?
Call (289) 653-1447

Panic & Exit Hardware: questions

Questions
Who is responsible for keeping the hardware compliant?

The building owner or the party the owner assigns, often a facilities manager, is responsible for keeping exit hardware in working order and for the fire door assembly testing that goes with it. A locksmith installs and services the hardware and can keep records on the owner's behalf, but the ongoing duty to maintain the assembly sits with whoever holds the building.

How much force does the door need to open with?

Hardware standards set a maximum, not a target: an exit device is built to release the latch under a firm push, no more than about 15 pounds of force applied at the touchpad or crossbar, roughly the pressure of a light shove rather than a heave. That ceiling covers people who cannot lean hard into a door, so the swing stays open to anyone moving toward it under pressure.

Is delayed-egress hardware allowed here?

Delayed-egress locking has a defined place in the codes that cover it, generally paired with sprinkler protection and a fire alarm system, and it is not a way to lock a door indefinitely; a short delay still releases on its own once the push is held, and always releases as soon as a fire alarm signal arrives. Whether it suits a given opening depends on the occupancy and the authority having jurisdiction, so it is confirmed with them before it is specified.

Related services

Panic & Exit Hardware near you

Call(289) 653-1447

Request a visit